CCBFW - WOOD FINISH, POLYURETHANE VARNISH, A67 V1 HIGH GLOSS
- MSDS: CCBFW
- Manufacturer: SHERWIN WILLIAMS CO
- Product Name: WOOD FINISH, POLYURETHANE VARNISH, A67 V1 HIGH GLOSS
- National Stock Number: 8010-01-035-2852
Product Identification
Product ID:WOOD FINISH, POLYURETHANE VARNISH, A67 V1 HIGH GLOSS
MSDS Date:01/03/1995
FSC:8010
NIIN:01-035-2852
MSDS Number: CCBFW
Responsible Party
CLEVELAND, OH 44115
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS).
CAS: 64742-47-8
RTECS: OA5504000
Fraction By Weight: 50-56%
OSHA PEL 100 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
SOLVENT NAPHTHA (PETROLEUM) MEDIUM ALIPHATIC; (MINERAL
CAS: 64742-88-7
Fraction By Weight: 50-56%
OSHA PEL 100 PPM (MFR)
ACGIH TLV: 100 PPM (MFR)
MAY CAUSE A HEALTH HAZARD. SYMPTOMS MAY NOT BE
RTECS: 9999999ZZ
INHALING CONTENTS CAN BE HARMFUL OR FATAL.
RTECS: 9999999ZZ
APPRVD CNTNRS W/COMPLETE & APPROP LABELING. DO
RTECS: 9999999ZZ
ONLY W/ADEQ VENT. AVOID BRTHG VAP & SPRAY MIST. AVOID
RTECS: 9999999ZZ
CLASSIFIED AS NUISANCE PARTICULATES WHICH MAY BE
RTECS: 9999999ZZ
DRIED FILM. IF NO SPECIFIC DUSTS ARE LISTED IN INGS,
RTECS: 9999999ZZ
(TOTAL DUST), OSHA PEL 15 MG/M3 (TOTAL DUST), 5 MG/M3
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
CONT, DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECS FOR
PROPER USE, VENT & PERSONAL PROT EQUIP. ACUTE:IRRIT OF EYES, SKIN &
RESP SYS. MAY CAUSE NERV SYS DEP RESS. EXTREME OVEREXP MAY RSLT IN
UNCON& POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OF EXCESS EXPOS TO VAPS/SPRAY MISTS.
REDNESS & ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESSIVE SKIN
EXPOS. CHRONIC:PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE EFTS TO
LIVER, URINARY & CVS. RPTS HAVE ASSOC RPTD & PRLNG OVEREXP TO
SOLVS W/PERM BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY DELIB CONC
& (ING 5)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
First Aid
First Aid:INHAL:REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
QUIET. SKIN:WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
CONTAMINATED CLOTHING & LAUNDER BEFORE RE-USE. EYES:FLUSH W/LARGE
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
INGEST:NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO
NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. GET MEDICAL
ATTENTION.
Fire Fighting
Flash Point:105F,41C
Lower Limits:0.9%
Upper Limits:7.1%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER SPRAY MAY BE INEFT. IF WATER IS USED, FOG NOZZ ARE PREF.
WATER MAY BE USED TO COOL CLSD CNTNRS TO (SUPDAT)
Unusual Fire/Explosion Hazard:FLAMM-CLASS 2. KEEP CNTNRS TIGHTLY CLSD.
ISOLATE FROM HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY
EXPLODE WHEN EXPOS TO EXTREME HEAT. APPLICATN(SUPDAT)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:COMBUST. KEEP AWAY FROM HEAT & OPEN
FLAME. VAPS WILL ACCUM READILY & MAY IGNITE EXPLOSIVELY. CONSULT
NFPA CODE. USE APPRVD BONDING & GROUNDING PROCS.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE:KEEP AREA
VENTED; DO NOT SMOKE; EXTING ALL FLAME, PILOT LIGHTS & HEATERS;
TURN OFF STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF
IGNIT. KEEP CNTNR CLSD WH EN NOT IN USE. TRANSFER ONLY TO (ING 6)
Exposure Controls
Respiratory Protection:IF PERSONAL EXPOS CANNOT BE CONTROLLED BELOW
APPLIC LIMS BY VENT, WEAR PROPERLY FITTED NIOSH APPRVD ORG
VAP/PARTICULATE RESP FOR PROT AGAINST INGS. WHEN SANDING/ABRADING
DRIED FILM, WEAR NIOSH APPRVD DUST/MIST RESP FOR DUST WHICH
(SUPDAT)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPT IF EXPOS TO INGS IS
MAINTAINED BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN EXPOS
TO EXTREME HEAT. WASTE DISP METH:REGARDING POLLUTION. RESP PROT:MAY
BE GENERATED FROM THIS PROD, UNDERLYING PAINT/ABRASIVE. VENT:1
910.94, 1910.107, 1910.108. EXPLO HAZ:TO HOT SURFS REQS SPECIAL
PRECS. DURING EMER CNDTNS OVEREXP TO DECOMP PRODS(ING 4)
Chemical Properties
Boiling Pt:B.P. Text:>200F,>93C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.86-0.88
VOC Grams/Liter:4.
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:50-80
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE: CARBON MONOXIDE, CARBON
DIOXIDE.
Disposal
Waste Disposal Methods:WASTE FROM THESE PRODS MAY BE HAZ AS DEFINED
UNDER THE RCRA (40 CFR 261). WASTE MUST BE TESTED FOR IGNITABILITY
TO DETERMINE APPLIC EPA HAZ WASTE NUMBERS. INCIN IN APPRVD
FACILITY. DO NOT INCIN CLSD C NTNRS. DISP OF I/A/W FED, STATE & LOC
REGS(SUPDAT)
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.